BECKETT GENISYS ADVANCED OIL BURNER CONTROL

Manufacturer: Beckett
Beckett 7505P152MU 120V Genisys Oil Burner Primary Control (Same As 7505P152M, 7505P-152M) Specifications - Lockout Time 15 Seconds Valve-On Delay Time 15 Seconds Motor-Off Delay Time 2 Minutes - ***NOTE*** Valve-on delay and motor-off relay timings on all models are programmable with Beckett snap-in programming display (Sold Separately) - Other factory set timings are available. - Contact Beckett for alternate timings. - Inputs Voltage: 102 to 132 Vac - Current: 150 mA plus burner motor, igniter, and valve loads - Frequency: 60 Hz - Outputs Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps (LRA) - Note – Reduce motor FLA rating by igniter current Igniter: 120 Vac, 3 A @ 0.7 PF min - Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min - Thermostat Anticipator Current: 0.1 A (If applicable) - Thermostat Voltage: 24 Vac (If applicable) Replaces: Honeywell R7184P1049, R7184P1072, R7184U1004, R7184U1012, R7184U1020, R7184P, R7184U1004, R7184U1012, R7184U1020, R7184U, Carlin 6020002, 6020002S, 60200-02S-010010, 6020002-S, Weil Mclain 643-900-317, 643900317 ***NOTE*** You Must Also Purchase The 52040 Alarm Module If Using The Alarm Feature On These Controls
SKU: BECKETT:7505P152MU
Product Availability: 2
$91.42
This product must be purchased in increments of 1
i h

Beckett 7505P152MU 120V Genisys Oil Burner Primary Control (Same As 7505P152M, 7505P-152M)

Specifications
- Lockout Time 15 Seconds Valve-On Delay Time 15 Seconds Motor-Off Delay Time 2 Minutes
- ***NOTE*** Valve-on delay and motor-off relay timings on all models are programmable with Beckett snap-in programming display (Sold Separately)
- Other factory set timings are available.
- Contact Beckett for alternate timings.
- Inputs Voltage: 102 to 132 Vac
- Current: 150 mA plus burner motor, igniter, and valve loads
- Frequency: 60 Hz
- Outputs Motor: 120 Vac, 10 full load amps (FLA*), 60 locked rotor amps (LRA)
- Note – Reduce motor FLA rating by igniter current Igniter: 120 Vac, 3 A @ 0.7 PF min - Solenoid Valve: 120 Vac, 1 A @ 0.7 PF min
- Thermostat Anticipator Current: 0.1 A (If applicable)
- Thermostat Voltage: 24 Vac (If applicable)

Replaces: Honeywell R7184P1049, R7184P1072, R7184U1004, R7184U1012, R7184U1020, R7184P, R7184U1004, R7184U1012, R7184U1020, R7184U, Carlin 6020002, 6020002S, 60200-02S-010010, 6020002-S, Weil Mclain 643-900-317, 643900317

***NOTE*** You Must Also Purchase The 52040 Alarm Module If Using The Alarm Feature On These Controls

Products specifications
Used in Beckett AFG
Used in Beckett AF
Used in Beckett AFII
Used in Beckett NX
Used in Beckett SF
Used in Beckett SR
Manufacturer Beckett