Search

HCPMS1215 Comfort-Aire by Heat Controller 12,000 BTU Mini-Split System With Heat Pump

Manufacturer: Century
Comfort-Aire by Heat Controller 12,000 BTU Mini-Split System With Heat Pump
SKU: CENTURY:HCPMS1215
Product Availability: Out of stock
$1,022.55
This product must be purchased in increments of 1
i h

PLEASE NOTE THESE UNITS WILL SHIP FOR FREE VIA TRUCK FREIGHT.
WE CANNOT SHIP THEM VIA UPS

Comfort-Aire by Heat Controller
Package Single Zone Ductless Mini-Split A/C With Heat Pump

12,000 BTU Package (15 SEER, 9 EER)

Package Includes:
1- Outdoor Unit (Condenser)
1- Indoor Unit (Blower, Air Handler)
1- Line Set
1- 30’ Coil of 14/4 TTHN Control Wire

For more than 75 years Heat Controller has been committed to being THE SOURCE for residential and commercial heating, cooling and dehumidification equipment. Under the Comfort-Aire and Century brands, we provide efficient, reliable products and in-season availability. Whether for heating or cooling, these products meet or exceed industry standards for energy efficiency.

Our "D" Series of ductless mini-splits, rated at 15 SEER, is ideal for locations where it's too expensive or impractical to install ductwork to add air conditioning...or where a window air conditioning unit can't be used.

The indoor unit of the "D" Series includes a Temperature Compensation feature that automatically adjusts to eliminate temperature stratification between ceiling and floor temperatures.

These cost-competitive systems are ideal for bedrooms, sunrooms, offices, arena skyboxes, historical properties, warehouse offices and more. A hole approximately 3 inches in diameter is all that's needed to connect the indoor and outdoor units.

The single zone "D" Series comes in cooling only and heat pump models, from 9,000 to 22,000 BTUH.

Features

Whisper Quiet—High tech fan in the indoor unit delivers balanced air flow
Temperature Compensation—Indoor unit adjusts automatically as needed to eliminate stratification between ceiling and floor temperatures
Random Swing—Continually adjusts air direction for a gentle, breeze-like effect
Multiple Modes—Cooling, dehumidification only, air circulation (heating in heat pump models) plus: Sleep mode, 24-hour timer and turbo mode
Auto Operation—Automatically adjusts to maintain a constant temperature/humidity level
Air Filtration—An air filter helps trap dust, pollen and other particles in the air; this permanent filter is designed to be washed on a regular basis and re-installed
Auto Restart—Reverts to the last setting following a power failure
Low Ambient Operation—Crankcase heater allow operation at 5°F (cooling)
Defrost—On heat pump models
                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                                             

‘DV’ Series 15 SEER Single Zone Ductless Mini-Split Systems With Heat Pump

FEATURES
Power Supply    115-1-60
Cooling Capacity (BTUH)12,000
EER9.0
HSPF/COP8.2/3.2
Cooling Amps11.7
Dehumidification (Pts/Hr.)2.54
Heating Capacity (BTUH)12,000
Heating Amps9.6
INDOOR UNIT
Air flow (CFM)                                                        341/294/235
Fan Speeds (Cool/Heat/Fan)3/3/3
Sound Level (dBa) H-M-L39/35/29
AIR DIRECTION
Vertical AdjustmentRemote
Horizontal (left/right)Manual
Auto Swing Up and DownStandard
INDICATOR LAMPS
ON/OFFStandard
24 Hr. Timer/Sleep ModeStandard
DefrostStandard
Temperature SettingRemote Temperature Set Range: 62°F to 86°F
INDOOR UNIT DIMENSIONS
Width (inches)30-5/16
Height (inches)10-1/8
Depth (inches)7-1/8
OUTDOOR UNIT DIMENSIONS
Width (inches)26
Height (inches)21-9/32
Depth (inches)10-7/16
ELECTRICAL DATA OUTDOOR UNIT*
* Always follow local, state and national electrical codes.
Main Power ConnectionOutdoor Unit
Min. Circuit Ampacity20.0
Max. Fuse/HACR Circuit Breaker30A
Indoor/Outdoor Connecting Cable Type*14 AWG / 4 conductor 600V INCLUDED
* Always follow local, state and national electrical codes.
LINE SETS O.D. (inch)
Liquid Connection (flare) (inch)1/4
Suction Connection (flare) (inch)1/2
Maximum Line Set Length*65.5 feet
Min. 10 ft. line set recommended.
Maximum Elevation (outdoor)*26 feet
Oil traps should be installed every 16.5 to 23 feet (5-7m) when the outdoor unit is installed above the indoor unit.

Products specifications
Manufacturer Century