-
Home
/
-
HSI120/240V 3-TRY 7SECTFI
HSI120/240V 3-TRY 7SECTFI
HSI,120/240V 3-TRY 7secTFI
- Pre-Purge 15 Sec
- Inter-Purge 15 Sec
- Post-Purge 60 Sec
- Input 24 VAC, 50/60 300mA
- Valve 24 VAC, 2.0 Amps Max
- INDUCER 120 VAC, 3.0 Amps or 240 VAC 1.5 Amps, 1/4 HP
- Ignitor 120 VAC 5.0 Amps Max
- Ambient Temperature -40 F to 176 F
- Ignition 7 Sec
- Heat Up 20 Sec
- 3 Tries
Features
- Safe start and full-time flame sensing
- 120/240 field selectable line voltage for use with 120 VAC ignitor option
- 24/120/240 VAC hot surface ignitor models available
- Blower control and airflow switch monitoring option
- Diagnostic LED
- Multiple trials for ignition
- Automatic reset option
- Local or remote flame sensing
- Flame current test pins
- Dual speed blower option for LoNox applications
- Fail-safe gas valve control (35-66 only)
- CE models available
Used With
- Pool and spa heaters
- Gas furnaces
- Water heaters
- Any 24 VAC gas burner application under 400K BTU
The Series 35-65 and 35-66 controls are designed to perform many gas-fired 24 VAC appliance functions in a single control, resulting in lower system cost. This series monitors the demand for heat, controls the combustion blower, monitors proper airflow, ignites and maintains the flame during heating, and provides diagnostic support. The on-board diagnostics with LED output provide assistance with troubleshooting and ensures safe and efficient burner operation. The microprocessor circuit design provides precise, repeatable
timing sequences for ignition and purge times (pre-, inter-, and post-) as well as multiple tries for ignition. The optional 120/240 VAC field selectable line voltage capability provides additional field service
efficiency and lower inventory costs.
SKU:
FENWAL:35-665535-113
This product must be purchased in increments of 1
HSI,120/240V 3-TRY 7secTFI
- Pre-Purge 15 Sec
- Inter-Purge 15 Sec
- Post-Purge 60 Sec
- Input 24 VAC, 50/60 300mA
- Valve 24 VAC, 2.0 Amps Max
- INDUCER 120 VAC, 3.0 Amps or 240 VAC 1.5 Amps, 1/4 HP
- Ignitor 120 VAC 5.0 Amps Max
- Ambient Temperature -40 F to 176 F
- Ignition 7 Sec
- Heat Up 20 Sec
- 3 Tries
Features
- Safe start and full-time flame sensing
- 120/240 field selectable line voltage for use with 120 VAC ignitor option
- 24/120/240 VAC hot surface ignitor models available
- Blower control and airflow switch monitoring option
- Diagnostic LED
- Multiple trials for ignition
- Automatic reset option
- Local or remote flame sensing
- Flame current test pins
- Dual speed blower option for LoNox applications
- Fail-safe gas valve control (35-66 only)
- CE models available
Used With
- Pool and spa heaters
- Gas furnaces
- Water heaters
- Any 24 VAC gas burner application under 400K BTU
The Series 35-65 and 35-66 controls are designed to perform many gas-fired 24 VAC appliance functions in a single control, resulting in lower system cost. This series monitors the demand for heat, controls the combustion blower, monitors proper airflow, ignites and maintains the flame during heating, and provides diagnostic support. The on-board diagnostics with LED output provide assistance with troubleshooting and ensures safe and efficient burner operation. The microprocessor circuit design provides precise, repeatable
timing sequences for ignition and purge times (pre-, inter-, and post-) as well as multiple tries for ignition. The optional 120/240 VAC field selectable line voltage capability provides additional field service
efficiency and lower inventory costs.