OIL BURNER PRIMARY CONTROL. ? CONTROLS OIL BURNER

Manufacturer: ICM Controls
REPLACES: ■ ICM1502 (30 seconds) • Honeywell: R8184G4074, R8184G1179, R8184G1302, R8184G4033 FEATURES: √ ICM1502 – 30 second lockout times √ Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat √ Solid state flame sensing circuit √ LED on terminal strip indicates system lockout √ Enclosed safety switch with external reset button burner housing) - C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required ■ Mounting bracket: For mounting on a standard 4” X 4” junction box or direct mounting on burner housing ■ Elec. rating, contacts (full load): 7.4 A @ 120 VAC; 3.7 A @ 240 VAC ■ Elec. rating, contacts (locked rotor): 44.4 A @ 120 VAC; 22.2 A @ 240 VAC ■ Temperature range: -30°F to +130°F (-34°C to +55°C) ■ Approvals: Underwriters Laboratories Inc SPECIFICATIONS: Ignition Type: Intermittent Timing, Safety Switch: 30 Mounting Bracket: Standard 4×4 J-Box or direct mounting on burner housing Electrical Rating (Contacts – Full Load): 7.4 A @ 120 VAC 3.7 A @ 240 VAC Electrical Rating (Contacts – Locked Rotor): 44.4 A @ 120 VAC 22.2 A @ 240 VAC Temperature Range: -30°F to 130°F Approvals: UL Approved
SKU: ICM:1502
Product Availability: 8
$84.67
This product must be purchased in increments of 1
i h

REPLACES:

■ ICM1502 (30 seconds) • Honeywell: R8184G4074, R8184G1179, R8184G1302, R8184G4033

FEATURES:

√ ICM1502 – 30 second lockout times

√ Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat

√ Solid state flame sensing circuit

√ LED on terminal strip indicates system lockout

√ Enclosed safety switch with external reset button
burner housing)

- C554A Cadmium Sulfide Flame Detector and 24 VAC thermostat required

■ Mounting bracket: For mounting on a standard 4” X 4” junction box or direct mounting on burner housing

■ Elec. rating, contacts (full load): 7.4 A @ 120 VAC; 3.7 A @ 240 VAC

■ Elec. rating, contacts (locked rotor): 44.4 A @ 120 VAC; 22.2 A @ 240 VAC

■ Temperature range: -30°F to +130°F (-34°C to +55°C)

■ Approvals: Underwriters Laboratories Inc

SPECIFICATIONS:
Ignition Type: Intermittent
Timing, Safety Switch: 30
Mounting Bracket: Standard 4×4 J-Box or direct mounting on burner housing

Electrical Rating (Contacts – Full Load):
7.4 A @ 120 VAC
3.7 A @ 240 VAC
Electrical Rating (Contacts – Locked Rotor):
44.4 A @ 120 VAC
22.2 A @ 240 VAC
Temperature Range: -30°F to 130°F
Approvals: UL Approved