Search

AQUASTAT. VERT OR HOR MOUNT 240F STOP 5-30F ADJ. DIFF LESS W

Manufacturer: Resideo
- Temperature Range Maximum 150 F - Includes Stop factory-set at 240 F (116 C); Heat-conductive compound - Mounting Horizontal or Vertical - Operating Temperature Range 100 F to 240 F - Bulb Size (in.) 3/8 in. x 2 7/8 in. copper - Differential Temperature 5 F to 30 F adj. - Switching Action SPST, contacts break on temperature rise. - Capillary Length (in.) 3 in. Electrical Ratings Millivolt--0.25 A @ 0.25 to 12 Vdc; At Full Load-- 8A @ 120 Vac: 5.1A @ 240 Vac; At Locked Rotor-- 48A @ 120 Vac: 30.6A @ 240 Vac Features - Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint. - Visible control point scale and external adjustment screw permit easy setting. - Horizontal or vertical insertion of the sensing element. - Direct or well immersion of the sensing element. - Models available for strap-on mounting. - Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications. - Select models include heat-conductive compound. Aquastat Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. L4006 are used in applications that utilize the existing wells
SKU: RESIDEO:L4006A1678
Product Availability: 6
$158.21
This product must be purchased in increments of 1
i h

- Temperature Range Maximum 150 F
- Includes Stop factory-set at 240 F (116 C); Heat-conductive compound
- Mounting Horizontal or Vertical
- Operating Temperature Range 100 F to 240 F
- Bulb Size (in.) 3/8 in. x 2 7/8 in. copper
- Differential Temperature 5 F to 30 F adj.
- Switching Action SPST, contacts break on temperature rise.
- Capillary Length (in.) 3 in.

Electrical Ratings Millivolt--0.25 A @ 0.25 to 12 Vdc; At Full Load-- 8A @ 120 Vac: 5.1A @ 240 Vac; At Locked Rotor-- 48A @ 120 Vac: 30.6A @ 240 Vac

Features
- Totally enclosed Micro Switch snap-acting switches operate on temperature rise to setpoint.
- Visible control point scale and external adjustment screw permit easy setting.
- Horizontal or vertical insertion of the sensing element.
- Direct or well immersion of the sensing element.
- Models available for strap-on mounting.
- Remote bulb model may be used to sense air temperature in ducts and in outside air sensing applications.
- Select models include heat-conductive compound.

Aquastat Controllers are immersion type devices for limiting or regulating the temperature of liquids in boilers, storage tanks, and other applications where temperature control is required. L4006 are used in applications that utilize the existing wells

Products specifications
Manufacturer Resideo