Home
/
-
DUAL AQUASTAT HI LIMIT 130-240F 10F FIXED DIFF CIRCULATOR 11
DUAL AQUASTAT HI LIMIT 130-240F 10F FIXED DIFF CIRCULATOR 11
- Temperature Range Maximum 150 F at switches; 265 F at sensing element
- Mounting Horizontal
- Operating Humidity Range (% RH)0 to 95% RH, non-condensing
- Operating Temperature Range High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F
- Differential Temperature 10 F Fixed
- Insulation Depth (in.)3 in.
- Electrical Ratings, Ignition: Transformer Load: 360 VA
- Switch Action: SPST
Electrical Ratings 0.25 A @ 0.25 to 12 Vdc; At Full Load-- 8A @ 120 Vac: 5.1A @ 240 Vac; At Locked Rotor-- 48A @ 120 Vac: 30.6A @ 240 Vac
Features
- An immersion type liquid-filled sensing element actuates two snap switches.
- One switch operates as a high limit control.
- The other switch operates as a low limit and/or circulator control, depending on the model.
- Controller may be mounted in any positioning and needs no leveling.
- Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch.
- Differential adjustment on low limit or circulator switch on select models.
- All adjustments accessible inside front cover.
- Push-in terminals for quick connecting.
- Single sensing element for easy installation.
- Two SPST snap switches act independently at respective temperature settings.
High limit, and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems.
This product must be purchased in increments of 1
- Temperature Range Maximum 150 F at switches; 265 F at sensing element
- Mounting Horizontal
- Operating Humidity Range (% RH)0 to 95% RH, non-condensing
- Operating Temperature Range High Limit-- 130 F to 240 F; Low Limit-- 110 F to 220 F
- Differential Temperature 10 F Fixed
- Insulation Depth (in.)3 in.
- Electrical Ratings, Ignition: Transformer Load: 360 VA
- Switch Action: SPST
Electrical Ratings 0.25 A @ 0.25 to 12 Vdc; At Full Load-- 8A @ 120 Vac: 5.1A @ 240 Vac; At Locked Rotor-- 48A @ 120 Vac: 30.6A @ 240 Vac
Features
- An immersion type liquid-filled sensing element actuates two snap switches.
- One switch operates as a high limit control.
- The other switch operates as a low limit and/or circulator control, depending on the model.
- Controller may be mounted in any positioning and needs no leveling.
- Separate, easy-to-read, calibrated dial and setpoint adjustments for each switch.
- Differential adjustment on low limit or circulator switch on select models.
- All adjustments accessible inside front cover.
- Push-in terminals for quick connecting.
- Single sensing element for easy installation.
- Two SPST snap switches act independently at respective temperature settings.
High limit, and/or circulator controllers used to regulate boiler water temperature in gas- or oil-fired hydronic heating systems.