TRIPLE AQUASTAT RELAY LINE VOLT BURNER CONTROL 120V 60HZ. 13
TRIPLE AQUASTAT RELAY LINE VOLT BURNER CONTROL 120V 60HZ. 13
- 120V
- 60Hz
- Maximum Safe Operating Pressure 200 PSI on outside of immersion well, 100 psi on capsule if inserted directly.
- Maximum Safe Operating Pressure (kPa)1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.
- Temperature Range Maximum 150 F at switches; 265 F at sensing element
- Includes 3 in. insertion well and ground screw.
- Mounting Vertical Mount
- Operating Humidity Range (% RH)0 to 95% RH, non-condensing
- Operating Temperature Range High Limit-- 130 F to 240 F adjustable; Low Limit-- 110 F to 220 F adjustable
- Differential Temperature High limit : 10 F fixed; low limit: 10-25 F adj
- Insulation Depth (in.)3 in.
Electrical Ratings, Burner At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Electrical Ratings, Circulator At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Features
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems.
- Provide multizone control by using a separate circulator and R845 Relay for each zone.
- Include diaphragm powerhead and Micro Switch assembly that respond to temperature changes in boiler water.
- Mount directly to boiler.
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves.
- Require 24 Vac thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E).
Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service.
Product Availability:
Out of stock
This product must be purchased in increments of 1
- 120V
- 60Hz
- Maximum Safe Operating Pressure 200 PSI on outside of immersion well, 100 psi on capsule if inserted directly.
- Maximum Safe Operating Pressure (kPa)1378 kPa on outside of immersion well, 690 kPa on capsule if inserted directly.
- Temperature Range Maximum 150 F at switches; 265 F at sensing element
- Includes 3 in. insertion well and ground screw.
- Mounting Vertical Mount
- Operating Humidity Range (% RH)0 to 95% RH, non-condensing
- Operating Temperature Range High Limit-- 130 F to 240 F adjustable; Low Limit-- 110 F to 220 F adjustable
- Differential Temperature High limit : 10 F fixed; low limit: 10-25 F adj
- Insulation Depth (in.)3 in.
Electrical Ratings, Burner At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Electrical Ratings, Circulator At Full Load-- 7.4 A @ 120 Vac: 3.7 A @ 240 Vac; At Locked Rotor-- 44.4 A @ 120 Vac: 22.2 A @ 240 Vac
Features
- Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems.
- Provide multizone control by using a separate circulator and R845 Relay for each zone.
- Include diaphragm powerhead and Micro Switch assembly that respond to temperature changes in boiler water.
- Mount directly to boiler.
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves.
- Require 24 Vac thermostat with heat anticipator set at 0.2 A (plus current draw of gas valve on L8124E).
Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water service.