Search

PROTECTORELAY OIL PRIMARY. 120V 60 HZ. SAFETY SWITCH TIMING:

Manufacturer: Resideo
- 120V - 60Hz - Temperature Range -40 F to +130 F - Mounts on standard 4 x 4 in. junction box - Timing, Safety Switch 45 sec. - Ignition Type Intermittent - Electrical Ratings, Contacts (full load) 7.4 A @ 120 Vac; 3.7 a @ 240 Vac - Electrical Ratings, Contacts (locked rotor) 44.4 A @ 120 Vac; 22.2 A @ 240 Vac - Enclosed safety switch with external reset button. - LED on terminal strip indicates system lockout. Features - Intermittent ignition is on while the burner is on. - Solid state flame sensing circuit. - External button to manually reset safety switch after lockout. - Enclosed safety switch must be manually reset after safety shutdown. - R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment. - Mounts on standard 4 x 4 in. junction box. - C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required. Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
SKU: RESIDEO:R8184M1051
Product Availability: 6
$222.56
This product must be purchased in increments of 1
i h

- 120V
- 60Hz
- Temperature Range -40 F to +130 F
- Mounts on standard 4 x 4 in. junction box
- Timing, Safety Switch 45 sec.
- Ignition Type Intermittent
- Electrical Ratings, Contacts (full load) 7.4 A @ 120 Vac; 3.7 a @ 240 Vac
- Electrical Ratings, Contacts (locked rotor) 44.4 A @ 120 Vac; 22.2 A @ 240 Vac
- Enclosed safety switch with external reset button.
- LED on terminal strip indicates system lockout.

Features
- Intermittent ignition is on while the burner is on.
- Solid state flame sensing circuit.
- External button to manually reset safety switch after lockout.
- Enclosed safety switch must be manually reset after safety shutdown.
- R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment.
- Mounts on standard 4 x 4 in. junction box.
- C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.

Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit

Products specifications
Manufacturer Resideo