TRADELINE. 120V/60HZ. SWITCHING OF TWO SPST LINE VOLT PLUS S

Manufacturer: Resideo
- 120V - 60Hz - Operating Humidity Range (% RH) 0 to 90% RH, non-condensing - Temperature Ratings Ambient: -20 F to +120 F - Contact Ratings (AFL) 7.4A AFL, 44.4A @ 120 Vac on each set of line-voltage contacts - Coil Ratings Voltage 24 Vac - Coil Ratings Current 0.4A - Electrical Ratings, Contacts Maximum connected load is 2000 VA Transformer Secondary Rating-24 Vac, 12 VA max., 9 VA available for external load. Secondary protected by replaceable 1A automotive fuse. Switching Two SPST, plus PowerPile rated low voltage SPST relay. (If normally closed contacts are needed, use RA889A). Features - Replaceable socketed relays. - Two troubleshooting LED. - Push-to-test button. - Replaceable transformer fuse. - Low-voltage contact rating for PowerPile applications. - Long-life DC relay drive control technology. - Relay for use with external 24 Vac or 24 Vdc supply, with line-voltage control, or with internal 24 V transformer supply. - One model replaces many competitor models The R8845U Universal Switching Relay with 24 V transformer provides intermediate switching of line-and low-voltage devices from a line- or low-voltage controller and is typically applied in Hydronic heating systems. Enclosed Universal switching relay with internal transformer for 24 volt 2 or 3 wire thermostat control of line voltage devices. Two line voltage SPST relays and one low voltage SPST relay with PowerPile rating. Thermostat Compatibility Honeywell electromechanical and electronic 2- or 3-wire; Thermostat Heat Anticipator Setting 0.12A
SKU: RESIDEO:R8845U1003
Product Availability: 1
$86.87
This product must be purchased in increments of 1
i h

- 120V
- 60Hz
- Operating Humidity Range (% RH) 0 to 90% RH, non-condensing
- Temperature Ratings Ambient: -20 F to +120 F
- Contact Ratings (AFL) 7.4A AFL, 44.4A @ 120 Vac on each set of line-voltage contacts
- Coil Ratings Voltage 24 Vac
- Coil Ratings Current 0.4A
- Electrical Ratings, Contacts Maximum connected load is 2000 VA

Transformer Secondary Rating-24 Vac, 12 VA max., 9 VA available for external load. Secondary protected by replaceable 1A automotive fuse.

Switching Two SPST, plus PowerPile rated low voltage SPST relay. (If normally closed contacts are needed, use RA889A).

Features
- Replaceable socketed relays.
- Two troubleshooting LED.
- Push-to-test button.
- Replaceable transformer fuse.
- Low-voltage contact rating for PowerPile applications.
- Long-life DC relay drive control technology.
- Relay for use with external 24 Vac or 24 Vdc supply, with line-voltage control, or with internal 24 V transformer supply.
- One model replaces many competitor models

The R8845U Universal Switching Relay with 24 V transformer provides intermediate switching of line-and low-voltage devices from a line- or low-voltage controller and is typically applied in Hydronic heating systems.

Enclosed Universal switching relay with internal transformer for 24 volt 2 or 3 wire thermostat control of line voltage devices. Two line voltage SPST relays and one low voltage SPST relay with PowerPile rating.

Thermostat Compatibility Honeywell electromechanical and electronic 2- or 3-wire; Thermostat Heat Anticipator Setting 0.12A

Products specifications
Manufacturer Resideo