- 24 VAC
- 60Hz
- Flame Failure Response Time (sec) 0.8 sec. @ 5.0 microamp
- Ambient Temperature Range (F) -40 F to +175 F
- Ignition Sequence Single trial for main burner ignition (then shut down and lockout)
- Single Rod
- Ignition Trials To Lockout 1
- Lockout Timing 11 sec.
- Ignition Trial Time (sec) 11 sec
- Maximum Valve Load @ 24 Vac (Amps) 2A
- Flame Failure Re-ignition Time (sec) 0.8 sec. maximum
Features
- Control ignition sequence and gas control operation.
- Generate high voltage potential for main burner ignition.
- Lockout after one trial for ignition if main burner fails to ignite.
- Reset from thermostat after lockout.
- Use modules (except S87C) with any combination gas control designed for direct spark applications and rated 2.0A or less.
Provide electronic control of direct spark ignition systems used on gas fire furnaces, boilers, and other heating appliances.