Home
/
-
STANDING PILOT GAS VALVE. STANDARD OPENING. 1/2 X 1/2 REG SE
STANDING PILOT GAS VALVE. STANDARD OPENING. 1/2 X 1/2 REG SE
VR8200A2132 STANDING PILOT GAS VALVE. STANDARD OPENING. 1/2 X 1/2 REG SE
Combination gas control for use in 24 Vac gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.
Features
Control includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
Compact size.
Provides two automatic valves.
Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.
Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
Meets codes requiring dual safety shut-off.
Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
All adjustments, wiring connections and pilot outlet are accessible from top of control.
Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
Compatible with ECO connector.
LITE-RITE (OFF-PILOT-ON) lighting sequence.
Operating Temperature Range (F ) 0 F to 175 F
Operating Temperature Range (C) -18 C to +79 C
Body Pattern Straight-through
Opening Characteristics Standard Opening
Pressure Ratings (psi)1/2 psi
Pressure Ratings (kPa)3.5 kPa
Inlet/Outlet Size (in.)1/2 in. x 1/2 in
Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing
Pressure Tapping 1/8 in. NPT with plug
Type of Fuel Natural (LP with included conversion kit)
Capacity (kBtuh) At 1 in. wc p.d.-- 130,000 BTUh: 20,000 BTUh minimum: 200,000 BTUh maximum Natural Gas
Pressure Regulator Standard
Pressure Regulator Setpoint (in. wc) 3.5 in. WC
Pressure Regulator Setpoint (kPa) 0.87 kPa
Ignition Type Standing Pilot
This product must be purchased in increments of 1
VR8200A2132 STANDING PILOT GAS VALVE. STANDARD OPENING. 1/2 X 1/2 REG SE
Combination gas control for use in 24 Vac gas-fired, standing pilot appliances with capacities from 30 to 300 cfh.
Features
- Control includes safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
- Compact size.
- Provides two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat, closes when call for heat ends.
- Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meets codes requiring dual safety shut-off.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
- Compatible with ECO connector.
- LITE-RITE (OFF-PILOT-ON) lighting sequence.
- Operating Temperature Range (F ) 0 F to 175 F
- Operating Temperature Range (C) -18 C to +79 C
- Body Pattern Straight-through
- Opening Characteristics Standard Opening
- Pressure Ratings (psi)1/2 psi
- Pressure Ratings (kPa)3.5 kPa
- Inlet/Outlet Size (in.)1/2 in. x 1/2 in
- Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing
- Pressure Tapping 1/8 in. NPT with plug
- Type of Fuel Natural (LP with included conversion kit)
- Capacity (kBtuh) At 1 in. wc p.d.-- 130,000 BTUh: 20,000 BTUh minimum: - - 200,000 BTUh maximum Natural Gas
- Pressure Regulator Standard
- Pressure Regulator Setpoint (in. wc) 3.5 in. WC
- Pressure Regulator Setpoint (kPa) 0.87 kPa
- Ignition Type Standing Pilot