INTERMITTENT PILOT GAS VALVE. STANDARD OPENING. 3/4 X 3/4 RE
INTERMITTENT PILOT GAS VALVE. STANDARD OPENING. 3/4 X 3/4 RE
- Single Stage
- Includes Two 3/4 in. x 1/2 in. reducer bushing; Natural to LP gas conversion kit.
- Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- 60Hz
- Electrical Connections 1/4 in. quick-connect male terminals
- 24 V
- Operating Temperature Range -40 F to +175 F
- Straight-through
- Standard Opening
- Pressure Ratings (psi)1/2 PSI
- Pressure Ratings (kPa) 3.5 kPa
- Inlet/Outlet Size (in.) 3/4 in. x 3/4 in.
- Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing
- Pressure Tapping 1/8 in. NPT with plug
- Type of Fuel Natural (LP with included conversion kit)
- Capacity (kBtuh)At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum: 415,000 BTUh maximum Natural Gas
- Pressure Regulator Standard
- Pressure Regulator Setpoint (in. wc) 3.5 in. wc
- Pressure Regulator Setpoint (kPa) 0.87 kPa
- Ignition Type Intermittent Pilot
Features
- Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
- Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.
- Compact size.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
- Compatible with ECO connector.
- ON-OFF lighting sequence.
Combination gas control for use in 24 Vac gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.
Product Availability:
Out of stock
This product must be purchased in increments of 1
- Single Stage
- Includes Two 3/4 in. x 1/2 in. reducer bushing; Natural to LP gas conversion kit.
- Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
- 60Hz
- Electrical Connections 1/4 in. quick-connect male terminals
- 24 V
- Operating Temperature Range -40 F to +175 F
- Straight-through
- Standard Opening
- Pressure Ratings (psi)1/2 PSI
- Pressure Ratings (kPa) 3.5 kPa
- Inlet/Outlet Size (in.) 3/4 in. x 3/4 in.
- Pilot Gas Outlet Compression fitting for 1/4 in. OD tubing
- Pressure Tapping 1/8 in. NPT with plug
- Type of Fuel Natural (LP with included conversion kit)
- Capacity (kBtuh)At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum: 415,000 BTUh maximum Natural Gas
- Pressure Regulator Standard
- Pressure Regulator Setpoint (in. wc) 3.5 in. wc
- Pressure Regulator Setpoint (kPa) 0.87 kPa
- Ignition Type Intermittent Pilot
Features
- Controls include safety shutoff, manual valve, two automatic operators, pressure regulator and pilot adjustment.
- Use with S86F,H; S860D; S8600F,H; S8610 and S90A,B Control Modules.
- Compact size.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm-operated second automatic valve opens under control of regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Adjustable servo regulator effectively maintains almost constant gas output pressure under wide fluctuations in gas supply pressure.
- Compatible with ECO connector.
- ON-OFF lighting sequence.
Combination gas control for use in 24 Vac gas-fired, intermittent pilot appliances with capacities from 30 to 415 cfh.