DIRECT IGNITION GAS VALVE. TWO STAGE. STANDARD OPENING. 3/4
DIRECT IGNITION GAS VALVE. TWO STAGE. STANDARD OPENING. 3/4
- Includes Two 3/4 x 1/2 in. reducer bushings; Natural to LP Conversion Kit
- 60Hz
- 24V
- Operating Temperature Range -40 F to +175 F
- Straight-Through
- 1/2" PSI
- Pressure Ratings (kPa) 3.5 kPa
- Inlet/Outlet Size (in.) 3/4 in. x 3/4 in
- Pressure Tapping 1/8 in. NPT with plug
- Capacity (kBtuh) At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum
- Pressure Regulator Setpoint (in. wc) 1.7 in. wc low; 3.5 in. wc high
- Pressure Regulator Setpoint (kPa) 0.48 kPa low; 0.87 kPa high
- Ignition Type Direct Ignition
- Anticipator Setting 0.62 A
Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Features
- Controls include manual valve, two automatic operators, and pressure regulator.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- ON-OFF lighting sequence.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Use VR8305 models with S89C,E,F and S87 series 5 and later.
Combination gas control for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances, with capacities from 30 to 415 cfh.
This product must be purchased in increments of 1
- Includes Two 3/4 x 1/2 in. reducer bushings; Natural to LP Conversion Kit
- 60Hz
- 24V
- Operating Temperature Range -40 F to +175 F
- Straight-Through
- 1/2" PSI
- Pressure Ratings (kPa) 3.5 kPa
- Inlet/Outlet Size (in.) 3/4 in. x 3/4 in
- Pressure Tapping 1/8 in. NPT with plug
- Capacity (kBtuh) At 1 in. wc p.d.-- 300,000 BTUh: 30,000 BTUh minimum
- Pressure Regulator Setpoint (in. wc) 1.7 in. wc low; 3.5 in. wc high
- Pressure Regulator Setpoint (kPa) 0.48 kPa low; 0.87 kPa high
- Ignition Type Direct Ignition
- Anticipator Setting 0.62 A
Mounting 0 to 90 degrees in any direction from the upright position of the gas control knob, including vertically.
Features
- Controls include manual valve, two automatic operators, and pressure regulator.
- Provide two automatic valves.
- Solenoid operated first automatic valve opens on thermostat call for heat; closes when call for heat ends.
- Diaphragm operated second automatic valve opens under control of the regulator; closes if gas or power supply is interrupted.
- Meet codes requiring dual safety shutoff.
- Natural to LP and LP to Natural conversion kits available for standard and slow opening gas valves.
- ON-OFF lighting sequence.
- All adjustments, wiring connections and pilot outlet are accessible from top of control.
- Use VR8305 models with S89C,E,F and S87 series 5 and later.
Combination gas control for use with hot surface/direct spark systems in 24 Vac, gas-fired appliances, with capacities from 30 to 415 cfh.