Home
/
-
SQUARE D CLOSED TANK FLOAT SWITCH 2 NPT
SQUARE D CLOSED TANK FLOAT SWITCH 2 NPT
- Device short name 9037H
- Device mounting Screw-in bushing
- Cable entry number 3 knock-outs for 1/2" conduit conforming to UL 508
- Contacts type and composition 2 NC, snap action, DPST-DB, Form YY
- NEMA 1
- 575V
- Tank Connection Size: 2-1/2" MNPT
- Controlled fluid Fresh water at specific gravity of 0.85 in or higher -18…104 °C
- Sea water at specific gravity of 0.85 in or higher -18…104 °C
- Hydraulic oil at specific gravity of 0.85 in or higher -18…104 °C
- Corrosive fluid at specific gravity of 0.85 in or higher -18…104 °C
Motor power kW 1.5 KW (2 hp) at 115 V AC, 1 phase
- 2.2 KW (3 hp) at 115 V AC, 3 phases
- 2.2 KW (3 hp) at 230 V AC, 1 phase
- 3.7 KW (5 hp) at 230 V AC, 3 phases
- 0.75 KW (1 hp) at 460 V AC, 3 phases
- 0.75 KW (1 hp) at 475 V AC, 3 phases
- 0.18 KW (0.25 hp) at 32 V DC
- 0.37 KW (0.5 hp) at 115 V DC
- 0.37 kW (0.5 hp) at 230 V DC
- Electrical connection Screw-clamp terminals, clamping capacity: 10 AWG
- Contact operation Contacts close on liquid rise
- Float movement 6...11.5 in adjustable
- Float position Right
- Float rod angle 90° (offset)
- Short-circuit protection 20 A cartridge fuse, type gG
- Local signaling With external pointe
- Materials in contact with fluid Cast iron
- Yellow brass
- Stainless steel 316
- Nitrile (Buna-N) or equivalent rubber
- Stainlesss steel 304
- Operating position Vertical position only
- Electrical durability 100 cycles, operating rate <60 cyc/mn
- Mechanical durability 300 cycles
- Terminal block type 4 terminals
- Maximum operating rate 60 cyc/mn
- [Ui] rated insulation voltage 575 V conforming to UL 508
9037HG31
Product Availability:
Out of stock
This product must be purchased in increments of 1
- Device short name 9037H
- Device mounting Screw-in bushing
- Cable entry number 3 knock-outs for 1/2" conduit conforming to UL 508
- Contacts type and composition 2 NC, snap action, DPST-DB, Form YY
- NEMA 1
- 575V
- Tank Connection Size: 2-1/2" MNPT
- Controlled fluid Fresh water at specific gravity of 0.85 in or higher -18…104 °C
- Sea water at specific gravity of 0.85 in or higher -18…104 °C
- Hydraulic oil at specific gravity of 0.85 in or higher -18…104 °C
- Corrosive fluid at specific gravity of 0.85 in or higher -18…104 °C
Motor power kW 1.5 KW (2 hp) at 115 V AC, 1 phase
- 2.2 KW (3 hp) at 115 V AC, 3 phases
- 2.2 KW (3 hp) at 230 V AC, 1 phase
- 3.7 KW (5 hp) at 230 V AC, 3 phases
- 0.75 KW (1 hp) at 460 V AC, 3 phases
- 0.75 KW (1 hp) at 475 V AC, 3 phases
- 0.18 KW (0.25 hp) at 32 V DC
- 0.37 KW (0.5 hp) at 115 V DC
- 0.37 kW (0.5 hp) at 230 V DC
- Electrical connection Screw-clamp terminals, clamping capacity: 10 AWG
- Contact operation Contacts close on liquid rise
- Float movement 6...11.5 in adjustable
- Float position Right
- Float rod angle 90° (offset)
- Short-circuit protection 20 A cartridge fuse, type gG
- Local signaling With external pointe
- Materials in contact with fluid Cast iron
- Yellow brass
- Stainless steel 316
- Nitrile (Buna-N) or equivalent rubber
- Stainlesss steel 304
- Operating position Vertical position only
- Electrical durability 100 cycles, operating rate <60 cyc/mn
- Mechanical durability 300 cycles
- Terminal block type 4 terminals
- Maximum operating rate 60 cyc/mn
- [Ui] rated insulation voltage 575 V conforming to UL 508
9037HG31