Home
/
-
SQUARE D CLOSED TANK FLOAT SWITCH 2 NPT
SQUARE D CLOSED TANK FLOAT SWITCH 2 NPT
Float switch, Pumptrol, closed tank, NEMA 1,
screw in bushing, 2 NC DPST DB contacts
Product specific application Liquid level control
Product destination For closed tank
Device mounting Screw-in bushing
Cable entry number 3 knock-outs for 1/2" conduit conforming to UL 508
Contacts type and composition 2 NC, snap action, DPST-DB, Form YY
Controlled fluid Fresh water at specific gravity of 0.85 in or higher -18…104 °C
Sea water at specific gravity of 0.85 in or higher -18…104 °C
Hydraulic oil at specific gravity of 0.85 in or higher -18…104 °C
Corrosive fluid at specific gravity of 0.85 in or higher -18…104 °C
Motor power kW 1.5 KW (2 hp) at 115 V AC, 1 phase
2.2 KW (3 hp) at 115 V AC, 3 phases
2.2 KW (3 hp) at 230 V AC, 1 phase
3.7 KW (5 hp) at 230 V AC, 3 phases
0.75 KW (1 hp) at 460 V AC, 3 phases
0.75 KW (1 hp) at 475 V AC, 3 phases
0.18 KW (0.25 hp) at 32 V DC
0.37 KW (0.5 hp) at 115 V DC
0.37 kW (0.5 hp) at 230 V DC
Electrical connection Screw-clamp terminals, clamping capacity: 10 AWG
Contact operation Contacts close on liquid rise
Float movement 6...11.5 in adjustable
Float position Left
Float rod angle 90° (offset)
Short-circuit protection 20 A cartridge fuse, type gG
Local signalling With external pointer
Materials in contact with fluid Stainlesss steel 304
Cast iron
Stainless steel 316
Yellow brass
Nitrile (Buna-N) or equivalent rubber
Enclosure material Polypropylene or equivalent
Operating position Vertical position only
Electrical durability 100 cycles, operating rate <60 cyc/mn
Mechanical durability 300 cycles
Terminal block type 4 terminals
Maximum operating rate 60 cyc/mn
[Ui] rated insulation voltage 575 V conforming to UL 508
Net weight 2.13 kg
Terminals description ISO n°1 Line-load-load-line
This product must be purchased in increments of 1
Float switch, Pumptrol, closed tank, NEMA 1,
screw in bushing, 2 NC DPST DB contacts
Product specific application Liquid level control
Product destination For closed tank
Device mounting Screw-in bushing
Cable entry number 3 knock-outs for 1/2" conduit conforming to UL 508
Contacts type and composition 2 NC, snap action, DPST-DB, Form YY
Controlled fluid Fresh water at specific gravity of 0.85 in or higher -18…104 °C
Sea water at specific gravity of 0.85 in or higher -18…104 °C
Hydraulic oil at specific gravity of 0.85 in or higher -18…104 °C
Corrosive fluid at specific gravity of 0.85 in or higher -18…104 °C
Motor power kW 1.5 KW (2 hp) at 115 V AC, 1 phase
2.2 KW (3 hp) at 115 V AC, 3 phases
2.2 KW (3 hp) at 230 V AC, 1 phase
3.7 KW (5 hp) at 230 V AC, 3 phases
0.75 KW (1 hp) at 460 V AC, 3 phases
0.75 KW (1 hp) at 475 V AC, 3 phases
0.18 KW (0.25 hp) at 32 V DC
0.37 KW (0.5 hp) at 115 V DC
0.37 kW (0.5 hp) at 230 V DC
Electrical connection Screw-clamp terminals, clamping capacity: 10 AWG
Contact operation Contacts close on liquid rise
Float movement 6...11.5 in adjustable
Float position Left
Float rod angle 90° (offset)
Short-circuit protection 20 A cartridge fuse, type gG
Local signalling With external pointer
Materials in contact with fluid Stainlesss steel 304
Cast iron
Stainless steel 316
Yellow brass
Nitrile (Buna-N) or equivalent rubber
Enclosure material Polypropylene or equivalent
Operating position Vertical position only
Electrical durability 100 cycles, operating rate <60 cyc/mn
Mechanical durability 300 cycles
Terminal block type 4 terminals
Maximum operating rate 60 cyc/mn
[Ui] rated insulation voltage 575 V conforming to UL 508
Net weight 2.13 kg
Terminals description ISO n°1 Line-load-load-line