IGNITION CONTROL-HONEYWELL S89F1098 USED ON STANDARD HSG SER
IGNITION CONTROL-HONEYWELL S89F1098 USED ON STANDARD HSG SER
62759-002 IGNITION CONTROL-HONEYWELL S89F1098 USED ON STANDARD HSG SER
Direct Spark Ignition
Provide electronic control of direct spark ignition systems, with external spark transformers, used on gas-fired furnaces, boilers, conversion burners and other heating appliances.
Features
Controls ignition sequence and gas control operation in direct spark ignition systems.
Control separate 120 Vac spark generator that provides high voltage potential for main burner ignition.
Lockout after one trial for ignition if main burner fails to ignite.
Reset from thermostat after lockout. Use separate electrodes for spark ignition and flame sensing.
Use any 24 Vac combination gas control designed for direct spark applications and rated at 2.0A or less.
Electrical Ratings: 24 Vac
Frequency: 60 Hz
Max Ambient Temperature: -40 F to +175 F
Flame Failure Re-ignition Time: 0.8 sec.
Maximum Valve Load @ 24 Vac (Amps): 2A
Ignition Trial Time: 4 Seconds
Flame Sense: Two Rod
Lockout Timing 4 Seconds
Pre-Purge Time 30 Seconds.